Lasany LI-P710 Touchscreen High-Speed Automatic Polarimeter with CFR Software
Free
Redefine laboratory polarimetry with the Lasany LI-P710 — an Android-powered automatic polarimeter featuring 8 selectable wavelengths (365–880 nm) for unmatched multi-wavelength optical rotation analysis. Delivering ±0.004° accuracy, Peltier temperature control (10–50°C, ±0.1°C), and a 10.1-inch color touchscreen, it handles the most demanding pharmaceutical and research workflows effortlessly. With 1,000 pre-stored methods, 128G storage, 500-user access control, Wi-Fi, Ethernet, and an optional 21 CFR Part 11 audit trail—it’s the complete compliance-ready analytical workstation. ISO 9001:2015 certified and WHO-GMP qualified.
🔬 Request a Quote Today | 9888911439 / 9803017479
Description
When your laboratory demands more than a standard polarimeter can offer, the Lasany LI-P710 Touchscreen High-Speed Automatic Polarimeter with CFR Software steps in as the definitive multi-wavelength analytical solution. Built by Lasany International—an ISO 9001:2015 certified and WHO-GMP compliant manufacturer—the LI-P710 is a smart, Android-powered polarimeter that seamlessly bridges the gap between everyday laboratory precision and full pharmaceutical regulatory compliance. Whether you are characterizing chiral APIs across multiple wavelengths, conducting temperature-controlled sugar concentration analysis, or managing a high-throughput multi-user laboratory environment, the LI-P710 delivers the accuracy, versatility, and compliance infrastructure your work demands — all through an intuitive 10.1-inch color touchscreen interface.
Key Features
- Eight Selectable Wavelengths (365 nm – 880 nm)—The LI-P710’s defining capability: a standard 589 nm Sodium D line plus seven optional wavelengths (365, 405, 436, 546, 578, 633, and 880 nm) allow comprehensive multi-wavelength optical rotation studies from a single instrument—eliminating the need for multiple specialized polarimeters.
- ±0.004° Accuracy with High-Quality Prisms—State-of-the-art optical control technology and precision prisms deliver consistently reliable measurements, making the LI-P710 fully compliant with USP, BP, EP, and IP pharmacopoeial optical rotation requirements.
- Peltier Temperature Control (10–50°C, ±0.1°C) — Industry-grade Peltier thermal regulation across the widest temperature range in the Lasany mid-range lineup ensures every measurement is thermally stable, reproducible, and internationally traceable—with no external water bath required.
- Android OS with 10.1-Inch Color Touchscreen — A powerful Android operating system transforms the LI-P710 into a fully networked analytical workstation, offering an intuitive, familiar interface that significantly reduces operator training time and daily workflow friction.
- 1,000 Pre-Stored Methods & 128G Data Storage — Support for up to 1,000 measurement methods and 128G onboard storage accommodates the largest analytical libraries and long-term data archiving requirements of busy pharmaceutical and research laboratories.
- 500-User Account Management with 4-Grade Access Control — Enterprise-ready personnel management ensures strict data integrity, role-based instrument access, and individual user accountability across large, multi-shift laboratory teams.
- CFR Software with Optional Audit Trail—Designed for 21 CFR Part 11 compliance, the LI-P710 supports complete electronic record management and optional audit trail functionality—essential for pharmaceutical batch release, stability testing, and regulatory authority inspections.
- Full Connectivity Suite—RS232, USB, U-disk, keyboard, mouse, Wi-Fi, and Ethernet interfaces enable seamless LIMS integration, network data sharing, and remote laboratory connectivity for modern paperless lab environments.
- 100,000-Hour LED Light Source—Long-life LED illumination at 589 nm (standard) guarantees consistent, stable light output with minimal maintenance, dramatically reducing total cost of ownership over the instrument’s operational lifetime.
- High-Speed Measurement at 8°/S — Completes 6 measurements in just 26 seconds, keeping pace with the most demanding high-throughput laboratory schedules without sacrificing accuracy or repeatability.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measuring Modes | Optical Rotation, Specific Rotation, Concentration, ISS, User Defined |
| Light Source | LED + Precision Interference Filters |
| Wavelength | Dual: Standard: 589 nm; Optional: 365, 405, 436, 546, 578, 633, 880 nm |
| Measuring Range | ±90° (OR) / ±259°Z (ISS) |
| Resolution | 0.001° |
| Accuracy | ±0.004° |
| Repeatability | ≤0.002° |
| Min. Transmittance | 0.1% |
| Response Speed | 8°/S |
| Measuring Time | 6 times / 26 seconds |
| Temperature Control | Peltier: 10–50°C |
| Temperature Accuracy | ±0.1°C |
| Operating System | Android |
| Display | 10.1-inch Color Touch LCD |
| Calibration | Multi-point Automatic |
| Data Storage | 128G |
| GMP Regulations | Qualified |
| Audit Trail | Optional |
| Interfaces | RS232, USB, U-disk, Keyboard, Mouse, Wi-Fi, Ethernet |
| Standard Test Tubes | 200 mm, 100 mm (regular), 100 mm (temp control) |
| Optional Test Tubes | 50 mm (regular), 200 mm (temp control) |
| Power Supply | 220V ±22V, 50Hz ±1Hz, 200W |
| Package Dimensions | 860 mm × 510 mm × 470 mm |
| Gross Weight | 35 kg |
Applications
The LI-P710 serves the broadest range of industries and analytical disciplines across the entire Lasany polarimeter lineup:
- Pharmaceutical QC & Regulatory Testing — Multi-wavelength optical rotation verification of APIs and chiral drug substances across pharmacopoeial monograph requirements, with full 21 CFR Part 11 data integrity support for batch release and regulatory submissions.
- Advanced Chiral Chemistry & Drug Discovery—Comparative optical rotation profiling of enantiomers and chiral intermediates across multiple wavelengths—enabling optical rotatory dispersion (ORD) studies critical for modern drug development programs.
- Sugar, Food & Beverage Manufacturing — Precise, temperature-controlled sucrose, fructose, and glucose concentration measurement using the International Sugar Scale for strict production quality assurance.
- Chemical, Petrochemical & Fine Chemical Industries — Optical rotation characterization of chiral reagents, solvents, and synthetic intermediates across diverse wavelength ranges for comprehensive compound profiling.
- Contract Research Organizations (CROs) — Multi-user, networked, compliance-driven environments where secure access management, audit trails, high accuracy, and multi-wavelength flexibility are simultaneously required for client-facing regulated analytical services.
- Academic, University & Government Research Laboratories — High-performance multi-wavelength polarimetry supporting advanced research in stereochemistry, biochemistry, natural products, and analytical chemistry.
- Essential Oil, Flavor & Fragrance Industry — Authentication and purity verification of optically active botanical extracts and terpene compounds using temperature-controlled, multi-wavelength optical rotation analysis.
Why Choose the Lasany LI-P710?
In a market filled with capable single-wavelength polarimeters, the LI-P710 stands alone through one transformative advantage: true multi-wavelength capability across eight selectable wavelengths from 365 nm to 880 nm. This single feature unlocks analytical possibilities — including optical rotatory dispersion profiling, multi-pharmacopoeial method compliance, and comparative chiral analysis — that are simply unavailable on any single-wavelength instrument, regardless of price.
Paired with Peltier temperature control spanning 10–50°C at ±0.1°C precision, the LI-P710 handles the widest range of thermally sensitive samples with confidence. Its Android-powered 10.1-inch interface, 128G storage, 1,000 pre-stored methods, and 500-user enterprise access control create a fully self-contained analytical workstation capable of running the most complex, multi-operator regulated laboratory workflows without external software or hardware additions.
GMP qualification status, optional 21 CFR Part 11 audit trail, and a comprehensive Wi-Fi/Ethernet connectivity suite ensure the LI-P710 is immediately ready for deployment in regulated pharmaceutical manufacturing, QC, and research environments. Backed by ISO 9001:2015 manufacturing quality and WHO-GMP compliance, every LI-P710 unit leaves Lasany International’s facility fully tested and certified for laboratory-grade performance.
For laboratories that require the versatility of multi-wavelength analysis, the assurance of pharmaceutical compliance, and the intelligence of an Android-powered workstation, the Lasany LI-P710 is the only instrument that delivers all three.










Reviews