Double Beam UV-VIS Spectrophotometer Model No. LI-2707 || Best Spectrophotometer Manufacturer In PAN India

In today’s modern laboratories, accuracy, stability, and ease of operation are essential for reliable analytical results. The Double Beam UV-VIS Spectrophotometer Model No. LI-2707, developed by Lasany International, is designed to meet these exact needs. With advanced optics, a large touch-screen interface, and high photometric precision, LI-2707 is an ideal solution for research, pharmaceutical, chemical, environmental, and quality control laboratories.

What is a Double Beam UV-VIS Spectrophotometer?

A double beam spectrophotometer simultaneously measures the sample and reference, eliminating fluctuations caused by light source instability. This ensures higher accuracy, better baseline stability, and repeatable results, making it the preferred choice for professional laboratories.

Key Highlights of LI-2707

  • Advanced Double Beam Optical System :- The LI-2707 uses a double beam photometric system combined with a Czerny-Turner monochromator, ensuring excellent wavelength accuracy and minimal stray light.
  • Wide Wavelength Range :- With a wavelength range of 190–1100 nm, this instrument supports both UV and visible spectrum analysis, suitable for a wide variety of applications.
  • User-Friendly Touch Screen :- The 8-inch color touch screen allows smooth wavelength setting, method selection, and real-time monitoring without the need for external software.

High Accuracy & Stability

Designed for critical analysis, the LI-2707 offers:

  • Wavelength accuracy of ±0.5 nm
  • Wavelength repeatability of ≤0.2 nm
  • Low baseline drift and noise for long-term measurements

Technical Specifications of LI-2707

  • Photometry: Double Beam
  • Monochromator Type: Czerny-Turner
  • Wavelength Range: 190 – 1100 nm
  • Spectrum Bandwidth: 1 nm
  • Grating: 1200 lines/mm
  • Detector: Silicon Photocell
  • Wavelength Accuracy: ±0.5 nm
  • Wavelength Repeatability: ≤0.2 nm
  • Scanning Speed: Fast / Medium / Slow
  • Stray Light: ≤0.02%T (220 nm NaI, 360 nm NaNO₂)
  • Photometric Range: ( 0.0 – 200.0 %T , −0.301 – 4.000 Abs , 0.000 – 9999 C )
  • Photometric Accuracy:  ( ±0.3% T ,  ±0.002 Abs (0–0.5A) , ±0.004 Abs (0.5–1A) 
  • Baseline Stability: ≤ ±0.0008 A (200–1090 nm)
  • Light Source: Hamamatsu Deuterium Lamp & Osram Tungsten Halogen Lamp
  • Interface: USB
  • Power Supply: AC 220V ±22V, 50Hz ±1Hz
  • Packaging Size: 730 × 630 × 450 mm
  • Weight: Approx. 42.5 kg

Compliance & Certifications

  • ISO 9001:2015 Certified Company
  • EN 61326-1:2013 Compliance
  • WHO-GMP Compatible

These certifications ensure the instrument meets international quality and safety standards.

Applications of LI-2707

The Double Beam UV-VIS Spectrophotometer LI-2707 is widely used in:

  • Pharmaceutical quality control
  • Chemical analysis
  • Environmental testing
  • Academic & research laboratories
  • Food & beverage testing
  • Biotechnology & life sciences

Why Choose Lasany International?

Lasany International is a trusted name in laboratory and analytical instruments, known for:

  • Reliable build quality
  • Competitive pricing
  • Strong after-sales support
  • Instruments designed for Indian and international markets

Conclusion

If you are looking for a high-performance, touch screen, double beam UV-VIS spectrophotometer, the LI-2707 is an excellent choice. Its precision, stability, and user-friendly operation make it a valuable asset for any modern laboratory.

For pricing, demonstrations, or export inquiries, contact Lasany International today.

Get in Touch with Us: –

Panchkula, Haryana
Website :- https://lasany.org/
Address :- SCF-132, Sector 17, Panchkula, Haryana 134109
Email :-  lasanyinternationalindia@gmail.com
Online Support :- 9888911439 / 9803017479

If you are looking for Laboratory, Analytical, and Medical Products, then Lasany International  is the perfect choice for you.

Unlocking Elemental Analysis: Atomic Absorption Spectroscopy in Scientific Laboratories

Atomic absorption spectroscopy (AAS) is an instrumental analysis technique ideal for determining trace elemental concentrations. With outstanding sensitivity and selectivity, atomic absorption is deployed across scientific laboratories to advance research and ensure quality.

How AAS (Atomic Absorption Spectroscopy) Works ?

In AAS, a liquid sample is aspirated into a flame, atomizing the elements. A light beam from a lamp containing the target element is directed through the flame into a monochromator and onto a detector. If that element is present in the sample, absorption occurs proportional to concentration.

Lasany International offers high-performance atomic absorption spectroscopy featuring powerful xenon lamps, double monochromators, and charge-coupled device array detectors. Lasany systems provide part-per-billion sensitivity, multi-element analysis, and a wide linear range.

Metals Analysis Across Industries

Quantifying metals is critical in fields from agriculture to electronics. For example, AAS analyzes nutrient metals like iron, zinc, and manganese in soils and plants to monitor deficiency. Toxic heavy metals including lead, mercury, arsenic and cadmium are measured to ensure the safety of foods.

In manufacturing, AAS monitors impurity metals in chemicals and raw materials to specifications down to ppb levels. Environmental testing utilizes AAS to evaluate hazardous metals in water and air pollution. Clinical labs use AAS to assess essential and toxic metal biomarkers in biological samples.

Not Just Metals: Carbon Detection in Diamonds

While best known for metals analysis, AAS also quantifies other elements. For the gem industry, the carbon concentration distinguishes natural diamonds from synthetic ones. Using a carbon hollow cathode lamp, AAS sensitively measures this nonmetal analyte.

Speciation Analysis by Hydride Generation

Certain elements like arsenic, selenium, and antimony form volatile hydrides, allowing enhanced sensitivity. Atomic absorption with hydride generation converts these elements into atomized hydrides for analysis down to ppt levels. This technique also provides valuable speciation data.

Kinetic Studies with Stopped-Flow AAS

With stopped-flow accessories, rapid kinetic processes are studied by mixing reagents, stopping the flow, and measuring absorption. Lasany’s stopped-flow AAS allows sub-second kinetic analysis of metal-ligand binding, catalytic reactions, and more. This research furthers our understanding of reaction mechanisms.

High-Throughput Analysis with Automated AAS Lasany’s auto-sampler, controlled by software, robotically handles samples from microplates and test tubes. Up to 240 samples can be measured unattended, enabling automated overnight studies. For industrial QA/QC, auto-sampling increases productivity and precision.

Microwave Digestion for Sample Preparation

Since AAS requires liquids, digestion converts solid samples into solutions. Microwave digestion uses high temperature and pressure to dissolve resistant solids efficiently. Integrated systems digest, transfer and measure samples straight from closed vessels minimizing contamination.

Complementary Techniques for Comprehensive Analysis

While extremely sensitive to metal concentrations, AAS provides limited qualitative information. Identifying unknown metals may require ICP techniques. Nonmetals analysis utilizes atomic fluorescence. Organic elemental analysis employs CHNOS systems. AAS combined with other spectroscopy and chromatography delivers complete characterization.

Lasany International’s diverse spectrometry portfolio includes innovative UV-visible spectrophotometer, fluorescence, and immunoassay platforms alongside AAS and ICP instrumentation. With unmatched analyte specificity, sensitivity, and versatility, atomic absorption empowers laboratories to explore frontiers in science and industry.

Enquire Now
close slider

    Select your currency
    INR Indian rupee
    X
    Add to cart