{"id":11457,"date":"2026-08-12T11:42:57","date_gmt":"2026-08-12T11:42:57","guid":{"rendered":"https:\/\/lasany.org\/?post_type=product&#038;p=11457"},"modified":"2026-08-18T07:39:04","modified_gmt":"2026-08-18T07:39:04","slug":"video-melting-point-li-mp14","status":"publish","type":"product","link":"https:\/\/lasany.org\/vi\/product\/video-melting-point-li-mp14\/","title":{"rendered":"Video Melting Point Apparatus Model LI-MP14"},"content":{"rendered":"<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\" data-sourcepos=\"5:1-5:1224;92-1315\">The <strong>Lasany LI-MP14 Video Melting Point Apparatus<\/strong> is an advanced, fully automated thermal analysis instrument that redefines melting point determination for pharmaceutical, chemical, and research laboratories requiring the highest levels of accuracy, regulatory compliance, and measurement documentation. Unlike conventional melting point instruments that rely solely on visual observation, the LI-MP14 integrates a <strong>720P HD camera<\/strong> with real-time video capture and playback monitoring \u2014 allowing operators to observe, record, and review the complete melting process in high-definition detail, eliminating subjective operator interpretation and ensuring fully objective, reproducible results. Powered by an Android operating system on a 10.1-inch touchscreen display, supporting up to 4 simultaneous capillary measurements, and compliant with National Pharmacopoeia, GMP, GLP, and FDA\/21CFR Part 11 requirements, the LI-MP14 is the benchmark video melting point apparatus for regulated pharmaceutical QC, academic research, and chemical analysis laboratories. Certified to ISO 9001:2015, WHO-GMP, and EN-61326-1:2013, it delivers analytical confidence and regulatory assurance in one powerful, future-ready instrument.<\/p>\n<h3 class=\"mt-3 -mb-1 text-[1.125rem] font-bold\" dir=\"ltr\" data-sourcepos=\"7:1-7:16;1317-1332\"><strong>Key Features<\/strong><\/h3>\n<ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\" data-sourcepos=\"9:1-19:169;1334-3193\">\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"9:1-9:177;1334-1510\"><strong>720P HD camera with video capture and playback\u2014<\/strong>records the complete melting event in high definition for objective, post-measurement review, and regulatory documentation<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"10:1-10:198;1511-1708\"><strong>4 simultaneous capillary measurements\u2014<\/strong>dramatically\u00a0increases throughput by testing four samples in a single run, reducing analysis time by up to 75% compared to single-capillary instruments<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"11:1-11:181;1709-1889\"><strong>Android-powered 10.1-inch touchscreen\u2014<\/strong>intuitive,\u00a0responsive interface with melting video playback, real-time curve display, and full instrument control from a single screen<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"12:1-12:164;1890-2053\"><strong>PID &amp; PWM dual temperature control\u2014<\/strong>ensures\u00a0precise, linear heating rates from 0.1\u00b0C\/min to 20\u00b0C\/min with \u00b10.3\u00b0C accuracy up to 200\u00b0C and \u00b10.5\u00b0C above 200\u00b0C<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"13:1-13:186;2054-2239\"><strong>0.01\u00b0C resolution\u2014<\/strong>the\u00a0highest resolution in Lasany&#8217;s melting point range, delivering ultra-fine temperature discrimination for demanding pharmaceutical and research applications<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"14:1-14:121;2240-2360\"><strong>200 measuring methods storage\u2014<\/strong>supports\u00a0extensive method libraries for multi-product pharmaceutical QC operations<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"15:1-15:206;2361-2566\"><strong>Adjustable light source brightness and detection sensitivity\u2014<\/strong>enables\u00a0reliable measurement of dark-colored, translucent, and challenging sample types that confound standard melting point instruments<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"16:1-16:178;2567-2744\"><strong>Electronic signature and optional audit trail\u2014<\/strong>meets\u00a0FDA\/21CFR Part 11, GMP, GLP, and National Pharmacopoeia compliance requirements for regulated laboratory environments<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"17:1-17:142;2745-2886\"><strong>User management for up to 200 users\u2014<\/strong>role-based\u00a0access control supports multi-operator regulated environments with full accountability<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"18:1-18:138;2887-3024\"><strong>128GB data storage with 40,000-set graph storage\u2014<\/strong>comprehensive\u00a0on-board data management for long-term method and result retention<\/li>\n<li class=\"font-claude-response-body whitespace-normal break-words pl-2\" data-sourcepos=\"19:1-19:169;3025-3193\"><strong>WIFI, RS232, USB, and RJ-45 connectivity\u2014<\/strong>flexible\u00a0data transfer and network integration options for laboratory information management system (LIMS) connectivity<\/li>\n<\/ul>\n<h3 class=\"mt-3 -mb-1 text-[1.125rem] font-bold\" dir=\"ltr\" data-sourcepos=\"21:1-21:28;3195-3222\"><strong>Technical Specifications<\/strong><\/h3>\n<div class=\"overflow-x-auto w-full px-2 mb-6 print:overflow-x-visible\" dir=\"ltr\" data-sourcepos=\"23:1-47:18;3224-4115\">\n<table class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\">\n<thead class=\"text-left\">\n<tr>\n<th class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\">Parameter<\/th>\n<th class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\" scope=\"col\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Model<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">LI-MP14<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Measuring Range<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Room Temperature \u2013 400\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Measuring Mode<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Auto \/ Visual (HD Camera, Video Capture, Playback)<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Measuring Methods<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">200<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Number of Users<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">200<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Resolution<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">0.01\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Accuracy<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">\u2264200\u00b0C: \u00b10.3\u00b0C; &gt;200\u00b0C: \u00b10.5\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Repeatability<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">0.3\u00b0C (at 1.0\u00b0C\/min heating rate)<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Linear Heating Rate<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">0.1\u00b0C\/min \u2013 20\u00b0C\/min<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Linear Heating Rate Error<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">\u00b15%<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Number of Capillaries<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">4 Simultaneous<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Capillary Dimensions<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">OD: \u03c61.4 mm, ID: \u03c61.0 mm, Length: 90mm<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Sample Height<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">3mm<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Operation System<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Android<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Display<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">10.1-inch Touchscreen<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Data Storage<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">128GB<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Graph Storage<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">40,000 Sets<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Audit Trail<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Optional<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Electronic Signature<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Yes.<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Interface<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">1\u00d7 RS232, 3\u00d7 USB, 1\u00d7 RJ-45, WIFI<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Power Supply<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">240V, 50Hz, 150W<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Dimensions<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">490 \u00d7 490 \u00d7 345 mm<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">Weight<\/td>\n<td class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\">7 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"mt-3 -mb-1 text-[1.125rem] font-bold\" dir=\"ltr\" data-sourcepos=\"49:1-49:16;4117-4132\"><strong>Applications<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\" data-sourcepos=\"51:1-51:1214;4134-5347\">The LI-MP14 Video Melting Point Apparatus serves a broad range of demanding analytical environments. In <strong>pharmaceutical quality control and manufacturing<\/strong>, it is used for melting point determination of active pharmaceutical ingredients (APIs), excipients, and raw materials in compliance with pharmacopoeial monographs including USP, BP, EP, and IP specifications \u2014 with full FDA\/21CFR Part 11 audit trail support for regulated documentation. <strong>Chemical and organic chemistry research laboratories<\/strong> rely on it for characterization and purity assessment of synthesized organic compounds, dye-stuffs, resins, polymers, and specialty chemicals. <strong>University chemistry and pharmacy departments<\/strong> use it for teaching and research applications where high-definition video playback enables clear student observation of the melting phenomenon. <strong>Cosmetics and perfume manufacturers<\/strong> employ it for quality characterization of waxes, fats, and aromatic crystalline substances. Its adjustable light source and detection sensitivity make it particularly effective for <strong>dark-colored, pigmented, and opaque samples<\/strong> that are difficult or impossible to assess accurately with conventional visual melting point instruments.<\/p>\n<h3 class=\"mt-3 -mb-1 text-[1.125rem] font-bold\" dir=\"ltr\" data-sourcepos=\"53:1-53:27;5349-5375\"><strong>Benefits of the LI-MP14<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\" data-sourcepos=\"55:1-55:1497;5377-6873\">The LI-MP14 represents a fundamental advancement over conventional and even automated single-capillary melting point apparatuses. Its <strong>720P HD video capture<\/strong> transforms melting point determination from a subjective, operator-dependent observation into an objective, documentable analytical measurement\u2014a critical distinction for pharmaceutical QC laboratories where method reproducibility and data integrity are regulatory requirements rather than aspirational targets. The ability to measure <strong>4 capillaries simultaneously<\/strong> is a significant operational efficiency gain for high-throughput QC departments running multiple raw material specifications per shift\u2014effectively quadrupling instrument productivity compared to single-capillary designs without increasing bench space requirements. The <strong>0.01\u00b0C resolution<\/strong> \u2014 five times finer than the LI-MP12&#8217;s 0.1\u00b0C resolution \u2014 enables the LI-MP14 to detect subtle melting point differences that indicate polymorphic variations, impurity levels, or formulation inconsistencies that coarser-resolution instruments would miss entirely. The optional <strong>FDA\/21CFR Part 11 compliant audit trail<\/strong> and <strong>electronic signature<\/strong> functionality make the LI-MP14 uniquely positioned for pharmaceutical manufacturers and contract research organizations operating under US FDA, EU GMP, or ICH regulatory frameworks \u2014 where data integrity requirements mandate complete, tamper-evident electronic records of all analytical measurements and operator interactions.<\/p>\n<h3 class=\"mt-3 -mb-1 text-[1.125rem] font-bold\" dir=\"ltr\" data-sourcepos=\"57:1-57:35;6875-6909\"><strong>Why Choose Lasany International<\/strong><\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\" data-sourcepos=\"59:1-59:753;6911-7663\">Lasany International is an ISO 9001:2015 and WHO-GMP certified laboratory instrument manufacturer with a proven track record of delivering internationally compliant, research-grade analytical instruments to pharmaceutical, chemical, and academic institutions across India and globally. The LI-MP14 carries CE marking and EN-61326-1:2013 certification and is backed by Lasany&#8217;s dedicated technical support team, ensuring seamless installation, user training, and ongoing instrument performance support. For pharmaceutical and research laboratories seeking a future-proof melting point solution that combines HD video analysis, regulatory compliance, and multi-sample throughput in a single Android-powered platform, the LI-MP14 is the definitive choice.<\/p>\n<p><strong>Get in Touch with Us: \u2013<\/strong><\/p>\n<p>Panchkula, Haryana<br \/>\nWebsite: https:\/\/lasany.org\/<br \/>\nAddress: SCF-132, Sector 17, Panchkula, Haryana 134109<br \/>\nEmail: lasanyinternationalindia@gmail.com, sales@lasany.org<br \/>\nOnline Support: 9888911439 \/ 9803017479<\/p>\n<p>If you are looking for laboratory, analytical, and medical products, then Lasany International is the perfect choice for you<\/p>\n","protected":false},"excerpt":{"rendered":"<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\">The Lasany LI-MP14 Video Melting Point Apparatus combines 720P HD camera video capture, 4 simultaneous capillary measurements, and 0.01\u00b0C resolution for the most comprehensive, objective melting point determination available. Measuring from room temperature to 400\u00b0C with \u00b10.3\u00b0C accuracy, PID &amp; PWM temperature control, and adjustable light sensitivity for dark-colored samples, it eliminates subjective observation errors entirely. Android-powered 10.1-inch touchscreen, 128GB storage, 40,000-set graph capacity, WIFI connectivity, electronic signature, and optional FDA\/21CFR Part 11 compliant audit trail make it the definitive choice for regulated pharmaceutical QC and research laboratories. ISO 9001:2015, WHO-GMP, and CE certified.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"><strong>Request a Quote today and capture every melting point with absolute precision.<\/strong><\/p>\n","protected":false},"featured_media":11464,"comment_status":"open","ping_status":"closed","template":"","meta":{"pgc_meta":"","_eb_attr":"","inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_cat":[94,635],"product_tag":[721,719,715,720,723,718,717,716,701,722,714],"class_list":["post-11457","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory-equipment","product_cat-melting-point-apparatus","product_tag-4-capillary-melting-point-apparatus","product_tag-720p-hd-melting-point-apparatus","product_tag-automatic-video-melting-point-meter","product_tag-digital-video-melting-point-instrument","product_tag-fda-21-cfr-part-11-melting-point-apparatus","product_tag-hd-camera-melting-point-apparatus","product_tag-lasany-li-mp14","product_tag-li-mp14","product_tag-pharmaceutical-melting-point-apparatus","product_tag-simultaneous-melting-point-analyzer","product_tag-video-melting-point-apparatus","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/comments?post=11457"}],"version-history":[{"count":2,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11457\/revisions"}],"predecessor-version":[{"id":11608,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11457\/revisions\/11608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media\/11464"}],"wp:attachment":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media?parent=11457"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product_cat?post=11457"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product_tag?post=11457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}