{"id":11445,"date":"2026-08-11T12:39:22","date_gmt":"2026-08-11T12:39:22","guid":{"rendered":"https:\/\/lasany.org\/?post_type=product&#038;p=11445"},"modified":"2026-08-18T07:46:38","modified_gmt":"2026-08-18T07:46:38","slug":"auto-melting-point-apparatus-li-mp12","status":"publish","type":"product","link":"https:\/\/lasany.org\/vi\/product\/auto-melting-point-apparatus-li-mp12\/","title":{"rendered":"Auto Melting Point Apparatus Model No. LI-MP12"},"content":{"rendered":"<div class=\"section\">\n<p class=\"prose\">The\u00a0<strong>Lasany LI-MP12 Auto Melting Point Apparatus<\/strong>\u00a0is a high-precision, fully automatic melting point determination instrument designed for the accurate measurement of melting points of pharmaceutical active ingredients, excipients, dye-stuffs, perfumes, waxes, and other organic crystal substances across a temperature range from ambient to 400\u00b0C. Manufactured by\u00a0<strong>Lasany International<\/strong> under ISO 9001:2015 and WHO-GMP certification in Panchkula, Haryana, the LI-MP12 employs dual PID and PWM temperature control for precise, stable heating at programmed linear rates from 0.1\u00b0C\/min to 20\u00b0C\/min\u2014delivering temperature accuracy of \u00b10.4\u00b0C below 200\u00b0C and \u00b10.7\u00b0C above 200\u00b0C with 0.1\u00b0C resolution. Controlled through a 7-inch color touch LCD interface, the LI-MP12 offers 8 selectable measuring methods and automatically records the complete melting curve for each sample\u2014calculating initial and final melting points without manual observation or operator judgement. With 1000-set on-board data storage, a built-in clock function for timestamped records, RS232 and USB interfaces for PC data transfer, and an optional thermal printer, the LI-MP12 delivers a complete, audit-ready melting point determination workflow for pharmaceutical quality control, regulatory compliance documentation, and organic chemistry research applications. A compact 7.5 kg gross weight and 580\u00d7445\u00d7320 mm package make the LI-MP12 straightforward to deploy on any laboratory bench.<\/p>\n<\/div>\n<div class=\"section\">\n<h3 class=\"section-title\"><strong>Key features<\/strong><\/h3>\n<div class=\"features-grid\">\n<ul>\n<li class=\"feat-card star\"><i class=\"ti ti-chart-line\"><\/i><strong>Auto melting curve recording: <\/strong>Automatically records the complete melting curve and calculates average initial and final melting points.<\/li>\n<li class=\"feat-card star\"><i class=\"ti ti-cpu\"><\/i><strong>PID &amp; PWM control: <\/strong>Dual\u00a0PID and PWM temperature control for precise, stable linear heating rate management.<\/li>\n<li class=\"feat-card star\"><i class=\"ti ti-list-numbers\"><\/i><strong>8 measuring methods:<\/strong>\u00a08\u00a0selectable measuring methods covering diverse sample types and pharmacopoeial protocols.<\/li>\n<li class=\"feat-card\"><i class=\"ti ti-hand-finger\"><\/i><strong>7-inch touch LCD <\/strong>Colour 7-inch touch LCD for intuitive method selection, parameter setting, and result display.<\/li>\n<li class=\"feat-card\"><i class=\"ti ti-database\"><\/i><strong>1000-set data storage <\/strong>Stores 1000 complete test data sets with clock-timestamped records for audit trail compliance.<\/li>\n<li class=\"feat-card\"><i class=\"ti ti-usb\"><\/i><strong>RS232 + USB output: <\/strong>Dual\u00a0RS232 and USB interface for PC connectivity and data export to laboratory systems.<\/li>\n<li class=\"feat-card\"><i class=\"ti ti-clock\"><\/i><strong>Built-in clock function <\/strong>Internal clock timestamps every test record for complete traceability and audit documentation.<\/li>\n<li class=\"feat-card\"><i class=\"ti ti-printer\"><\/i><strong>Optional thermal printer <\/strong>Optional thermal printer accessory for direct hard-copy printing of melting point certificates.<\/li>\n<\/ul>\n<\/div>\n<div>\n<div><strong>Measuring range highlights<\/strong><\/div>\n<div class=\"methods-row\"><span class=\"method-chip\">RT \u2013 400\u00b0C 0.1\u00b0C<\/span><span class=\"method-chip\"> resolution 0.1\u201320\u00b0C\/min<\/span><span class=\"method-chip\"> heating rate \u00b10.4\u00b0C<\/span><span class=\"method-chip\"> accuracy \u2264200\u00b0C \u00b10.7\u00b0C<\/span><span class=\"method-chip\"> accuracy &gt;200\u00b0C 0.3\u00b0C<\/span><span class=\"method-chip\">\u00a0repeatability<\/span><\/div>\n<\/div>\n<\/div>\n<div class=\"section\">\n<div><\/div>\n<h3 class=\"section-title\"><strong>Technical specifications<\/strong><\/h3>\n<div>\n<table class=\"specs-table\">\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>LI-MP12<\/td>\n<\/tr>\n<tr class=\"hl\">\n<td>Measuring range<\/td>\n<td>RT \u2013 400\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Measuring mode<\/td>\n<td>Auto<\/td>\n<\/tr>\n<tr>\n<td>Measuring methods<\/td>\n<td>8<\/td>\n<\/tr>\n<tr class=\"hl\">\n<td>Resolution<\/td>\n<td>0.1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Linear heating-up rate<\/td>\n<td>0.1\u00b0C\/min \u2013 20\u00b0C\/min<\/td>\n<\/tr>\n<tr class=\"hl\">\n<td>Accuracy (\u2264200\u00b0C)<\/td>\n<td>\u00b1 0.4\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy (&gt;200\u00b0C)<\/td>\n<td>\u00b1 0.7\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Repeatability<\/td>\n<td>0.3\u00b0C (at 1.0\u00b0C\/min heating rate)<\/td>\n<\/tr>\n<tr>\n<td>Linear heating rate error<\/td>\n<td>\u00b1 10%<\/td>\n<\/tr>\n<tr>\n<td>Number of capillaries<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Capillary dimensions<\/td>\n<td>OD \u03c61.4 mm \u00b7 ID \u03c61.0 mm \u00b7 Length 90 mm<\/td>\n<\/tr>\n<tr>\n<td>Height of sample<\/td>\n<td>3 mm<\/td>\n<\/tr>\n<tr>\n<td>Data storage<\/td>\n<td>1000 sets<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>7-inch colour touch LCD<\/td>\n<\/tr>\n<tr>\n<td>Interface<\/td>\n<td>RS232 \u00b7 USB<\/td>\n<\/tr>\n<tr>\n<td>Printer<\/td>\n<td>Thermal (optional accessory)<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>240VAC, 50Hz, 100W<\/td>\n<\/tr>\n<tr>\n<td>Package dimensions<\/td>\n<td>580 \u00d7 445 \u00d7 320 mm<\/td>\n<\/tr>\n<tr>\n<td>Gross weight<\/td>\n<td>7.5 kg<\/td>\n<\/tr>\n<tr>\n<td>Certifications<\/td>\n<td>ISO 9001:2015 \u00b7 WHO-GMP \u00b7 CE \u00b7 EN-61326-1:2013<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"section\">\n<h3 class=\"section-title\"><strong>Applications<\/strong><\/h3>\n<div class=\"apps-row\">\n<ul>\n<li class=\"app-pill\"><i class=\"ti ti-pill\"><\/i>Pharmaceutical API &amp; excipient testing<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-certificate\"><\/i>Pharmacopoeial identity testing<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-atom\"><\/i>Organic chemistry research<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-paint\"><\/i>Dye-stuffs &amp; pigments<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-spray\"><\/i>Perfumes &amp; cosmetics<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-building-factory-2\"><\/i>Chemical manufacturing QC<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-droplet\"><\/i>Wax &amp; polymer testing<\/li>\n<li class=\"app-pill\"><i class=\"ti ti-school\"><\/i>Academic chemistry labs<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"section\">\n<h3 class=\"section-title\"><strong>Why choose the LI-MP12?<\/strong><\/h3>\n<div class=\"benefits-list\">\n<ul>\n<li class=\"benefit-item\"><strong>A full melting curve eliminates observer subjectivity\u2014<\/strong>traditional capillary melting point apparatus requires an operator to visually observe and manually record the temperature at which melting begins and ends\u2014introducing significant inter-operator variability. The LI-MP12&#8217;s automatic melting curve recording and automatic initial\/final melting point calculation completely eliminate this subjectivity, delivering reproducible, operator-independent results that meet modern pharmaceutical quality system requirements.<\/li>\n<li class=\"benefit-item\"><strong>PID &amp; PWM dual control delivers precise linear heating rates\u2014pharmacopoeial<\/strong> melting point methods specify precise heating rates (typically 1\u00b0C\/min or 2\u00b0C\/min) because heating rate affects the observed melting point temperature. The LI-MP12&#8217;s PID and PWM dual control system maintains these specified rates with a linear heating rate error of only \u00b110%\u2014significantly more stable than single-controller instruments\u2014ensuring that melting point values are directly comparable to pharmacopoeial reference standards.<\/li>\n<li class=\"benefit-item\"><strong>1000-set storage with clock enables complete test traceability\u2014pharmaceutical<\/strong>\u00a0quality control laboratories operating under GMP require complete traceability of melting point measurements, including sample identity, test date, operator, and result. The LI-MP12&#8217;s 1000-set timestamped data storage, RS232\/USB export, and optional thermal printer provide a complete, audit-ready data management chain for regulatory inspection readiness.<\/li>\n<li class=\"benefit-item\"><strong>RT\u2013400\u00b0C range covers the widest pharmaceutical substance range<\/strong>\u00a0\u2014 from low-melting waxes and lipids below 50\u00b0C to high-melting inorganic pharmaceutical excipients approaching 400\u00b0C, the LI-MP12&#8217;s full RT\u2013400\u00b0C range covers virtually every substance type encountered in pharmaceutical, chemical, and organic chemistry laboratories \u2014 eliminating the need for multiple instruments at different temperature ranges.<\/li>\n<li class=\"benefit-item\"><strong>ISO 9001:2015 &amp; WHO-GMP certified Indian manufacturer<\/strong>\u00a0\u2014 manufactured by Lasany International in Panchkula with CE and EN-61326-1:2013 certification, backed by Lasany&#8217;s dedicated after-sales technical support and service network across India and international export markets.<\/li>\n<\/ul>\n<\/div>\n<div>\n<p><strong>Get in Touch with Us: \u2013<\/strong><\/p>\n<p>Panchkula, Haryana<br \/>\nWebsite: https:\/\/lasany.org\/<br \/>\nAddress: SCF-132, Sector 17, Panchkula, Haryana 134109<br \/>\nEmail: lasanyinternationalindia@gmail.com, sales@lasany.org<br \/>\nOnline Support: 9888911439 \/ 9803017479<\/p>\n<p>If you are looking for laboratory, analytical, and medical products, then Lasany International is the perfect choice for you<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\">The Lasany LI-MP12 Auto Melting Point Apparatus delivers highly accurate, fully automated melting point determination from room temperature to 400\u00b0C with \u00b10.4\u00b0C accuracy and 0.1\u00b0C resolution. Powered by PID &amp; PWM temperature control with 8 measuring methods, it automatically records the melting curve and calculates average initial and final melting points\u2014eliminating manual observation errors. A 7-inch touchscreen LCD, 1000-set data storage, RS232\/USB connectivity, and computer data transfer capability make it ideal for pharmaceutical, dye-stuff, perfume, and organic chemistry laboratories requiring fast, reproducible thermal characterization. ISO 9001:2015, WHO-GMP, and CE certified.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"><strong>Request a quote today and automate your melting point analysis.<\/strong><\/p>\n","protected":false},"featured_media":11446,"comment_status":"open","ping_status":"closed","template":"","meta":{"pgc_meta":"","_eb_attr":"","inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"product_cat":[94,635],"product_tag":[694,699,695,697,696,698,701,700],"class_list":["post-11445","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory-equipment","product_cat-melting-point-apparatus","product_tag-auto-melting-point-apparatus","product_tag-automated-melting-point-analyzer","product_tag-automatic-melting-point-meter","product_tag-digital-melting-point-apparatus","product_tag-li-mp12","product_tag-melting-point-determination-instrument","product_tag-pharmaceutical-melting-point-apparatus","product_tag-pid-pwm-melting-point-apparatus","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/comments?post=11445"}],"version-history":[{"count":2,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11445\/revisions"}],"predecessor-version":[{"id":11604,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product\/11445\/revisions\/11604"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media\/11446"}],"wp:attachment":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media?parent=11445"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product_cat?post=11445"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/product_tag?post=11445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}