{"id":10896,"date":"2026-06-03T08:53:03","date_gmt":"2026-06-03T08:53:03","guid":{"rendered":"https:\/\/lasany.org\/?p=10896"},"modified":"2026-06-06T06:53:30","modified_gmt":"2026-06-06T06:53:30","slug":"double-beam-uv-spectrophotometer-complete-guide-to-precision-optical-analysis","status":"publish","type":"post","link":"https:\/\/lasany.org\/vi\/double-beam-uv-spectrophotometer-complete-guide-to-precision-optical-analysis\/","title":{"rendered":"Double Beam UV Spectrophotometer : Complete Guide to Precision Optical Analysis"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">In any analytical laboratory, the ability to measure how substances interact with light is fundamental to almost every scientific discipline. From testing the purity of a pharmaceutical compound to monitoring pollutants in water, quantifying protein concentrations in biological samples, or controlling the quality of industrial chemicals, light-based measurement is at the core of it all. And when precision is non-negotiable, scientists reach for the <\/span><a href=\"https:\/\/lasany.org\/product\/double-beam-microprocessor-uv-vis-touch-screen-spectrophotometer-with-software\/\"><b>Double Beam UV Spectrophotometer<\/b><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This advanced analytical instrument has earned its reputation as the gold standard in optical analysis by solving one of the most persistent challenges in spectrophotometry\u2014real-time correction for light source instability. Its unique optical design, which splits the light beam simultaneously through a sample and a reference, delivers measurement stability and reproducibility that no single beam instrument can match.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In this complete guide, <\/span><a href=\"https:\/\/lasany.org\/\"><b>Lasany International<\/b><\/a><span style=\"font-weight: 400;\">\u2014one of India&#8217;s most respected manufacturers and exporters of laboratory and analytical instruments\u2014explores everything you need to know about the <\/span>Double Beam UV Spectrophotometer,<span style=\"font-weight: 400;\">\u00a0its working principle, key components, standout features, applications across industries, and how to select the right model for your laboratory&#8217;s exact needs.<\/span><\/p>\n<h2><b>What Is a Double Beam UV Spectrophotometer?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> is a precision analytical instrument that measures the absorbance and transmittance of ultraviolet and visible light through a sample across a wavelength range that typically spans from 190 nm to 1100 nm. It is built on the foundational principle of the Beer-Lambert Law\u2014which establishes a direct, quantifiable relationship between the concentration of a substance in solution and the amount of light it absorbs at a specific wavelength.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">What makes the <\/span><strong><a href=\"https:\/\/lasany.org\/product\/double-beam-microprocessor-uv-vis-touch-screen-spectrophotometer-with-software\/\">Double Beam UV Spectrophotometer<\/a><\/strong><span style=\"font-weight: 400;\"> unique is its optical architecture. Unlike a single beam instrument that measures the sample and reference alternately, the double beam design uses a beam splitter to divide the light from the source into two simultaneous, equal-intensity beams. One beam travels through the sample cuvette, and the other passes through the reference cuvette\u2014at exactly the same moment. The instrument continuously compares both signals in real time, automatically compensating for any fluctuations in lamp intensity, detector response, or environmental conditions.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The result is a level of measurement stability, baseline correction, and analytical reproducibility that makes the <\/span>UV-Vis double beam spectrophotometer<span style=\"font-weight: 400;\"> the instrument of choice for pharmaceutical research, biochemical analysis, environmental testing, food quality control, and advanced scientific research worldwide.<\/span><\/p>\n<h2><b>How Does a Double Beam UV Spectrophotometer Work?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Understanding the working principle of the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> helps users configure measurements correctly and get the most accurate results from every session. Here is the complete light path, step by step:<\/span><\/p>\n<p><b>Step 1 \u2014 Dual Light Source:<\/b><span style=\"font-weight: 400;\"> The instrument uses two complementary lamps\u2014a Deuterium lamp for the UV range (190\u2013400 nm) and a Tungsten-Halogen lamp for the visible range (400\u20131100 nm). These lamps switch automatically based on the selected wavelength, providing seamless spectral coverage across the full working range of the <\/span>double beam UV-Vis spectrometer<span style=\"font-weight: 400;\">.<\/span><\/p>\n<p><b>Step 2\u2014Monochromator:<\/b><span style=\"font-weight: 400;\"> Polychromatic light from the source enters a high-resolution diffraction grating monochromator\u2014typically with 1200 or 1600 lines\/mm\u2014which disperses the light and isolates a narrow, precise wavelength band to pass through to the beam splitter.<\/span><\/p>\n<p><b>Step 3 \u2014 Beam Splitting:<\/b><span style=\"font-weight: 400;\"> A half-mirror or rotating sector mirror divides the monochromatic beam into two equal beams simultaneously. This is the defining feature of the <\/span>Double Beam UV Spectrophotometer\u2014the<span style=\"font-weight: 400;\">\u00a0synchronization of sample and reference measurement at every instant.<\/span><\/p>\n<p><b>Step 4 \u2014 Sample and Reference Interaction:<\/b><span style=\"font-weight: 400;\"> One beam passes through the sample cuvette containing the test solution. The other passes through the reference cuvette containing the blank or pure solvent. The sample absorbs light at wavelengths specific to its chemical composition, reducing the transmitted beam intensity.<\/span><\/p>\n<p><b>Step 5 \u2014 Detection:<\/b><span style=\"font-weight: 400;\"> A silicon photodiode or photomultiplier tube (PMT) converts transmitted light from both beams into electrical signals. The <\/span>UV-Vis dual beam spectrophotometer<span style=\"font-weight: 400;\"> processor computes absorbance (A = log I\u2080\/I) and percentage transmittance (%T) from the ratio of the two signals.<\/span><\/p>\n<p><b>Step 6 \u2014 Display and Data Output:<\/b><span style=\"font-weight: 400;\"> Results are instantly displayed on the instrument screen and can be stored internally or exported via USB or RS-232 to a connected computer for spectral scanning, kinetics plotting, and report generation using dedicated analytical software.<\/span><\/p>\n<h2><b>Key Features of the Double Beam UV Spectrophotometer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Modern <\/span>Double Beam UV Spectrophotometers<span style=\"font-weight: 400;\"> from leading manufacturers like <\/span>Lasany International<span style=\"font-weight: 400;\"> are packed with advanced features that make them powerful, user-friendly, and compliance-ready:<\/span><\/p>\n<p><b>Wide Wavelength Range (190\u20131100 nm)<\/b><span style=\"font-weight: 400;\">\u2014Full UV and visible spectral coverage in a single <\/span>dual beam UV spectrophotometer<span style=\"font-weight: 400;\"> eliminates the need for multiple instruments across diverse analytical applications.<\/span><\/p>\n<p><b>Automatic Baseline Correction<\/b><span style=\"font-weight: 400;\"> \u2014 The simultaneous dual-beam design provides continuous, automatic compensation for lamp drift and intensity fluctuations\u2014eliminating the most common source of error in single beam instruments.<\/span><\/p>\n<p><b>High Spectral Resolution<\/b><span style=\"font-weight: 400;\"> \u2014 Holographic diffraction gratings with 1200\u20131600 lines\/mm deliver narrow spectral bandwidths (as low as 0.5\u20131 nm), giving the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> exceptional ability to resolve closely spaced absorption peaks.<\/span><\/p>\n<p><b>Photometric Accuracy<\/b><span style=\"font-weight: 400;\"> \u2014 Industry-standard photometric accuracy of \u00b10.002 Abs at 0.5 Abs ensures reliable quantitative analysis across a photometric range of \u22124 to +4 Abs.<\/span><\/p>\n<p><b>Multi-Mode Operation<\/b><span style=\"font-weight: 400;\"> \u2014 Leading <\/span>double beam UV-Vis spectrometers<span style=\"font-weight: 400;\"> support photometry, quantitative analysis, wavelength scanning, kinetics, multi-wavelength measurement, and DNA\/protein analysis modes\u2014all from a single integrated platform.<\/span><\/p>\n<p><b>Touchscreen Interface<\/b><span style=\"font-weight: 400;\"> \u2014 Advanced models from <\/span>Lasany International<span style=\"font-weight: 400;\"> feature large 8-inch colour touchscreen displays with intuitive menu navigation, graphical spectral display, and interactive data analysis\u2014making complex measurements straightforward for any operator.<\/span><\/p>\n<p><b>PC Connectivity and Software<\/b><span style=\"font-weight: 400;\"> \u2014 USB and RS-232 interfaces enable seamless data transfer to computers. Dedicated software supports spectral scanning, multi-point calibration, GLP-compliant data logging, and comprehensive report generation.<\/span><\/p>\n<p><b>GLP\/GMP Compliance<\/b><span style=\"font-weight: 400;\"> \u2014 Date\/time stamping, user access controls, audit trails, and instrument diagnostics make the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> audit-ready for ISO, NABL, GMP, and GLP-accredited laboratories without additional investment.<\/span><\/p>\n<h2><b>Applications of the Double Beam UV Spectrophotometer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> is one of the most universally applied instruments in modern science. Its cross-industry versatility is unmatched:<\/span><\/p>\n<h3><b>Pharmaceutical Research and Quality Control<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The pharmaceutical industry depends on the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> for identification and assay of active pharmaceutical ingredients (APIs), purity testing of raw materials, dissolution studies, impurity profiling, and stability testing\u2014all in compliance with USP, BP, and IP pharmacopoeial requirements. Consistent, baseline-corrected absorbance data is critical for drug safety and regulatory submission.<\/span><\/p>\n<h3><b>Biochemistry and Life Sciences<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">In biological research, the <\/span>UV-Vis double beam spectrophotometer<span style=\"font-weight: 400;\"> is essential for nucleic acid quantification (DNA and RNA measured at 260 nm), protein estimation using Bradford, BCA, and Lowry assays, enzyme kinetics monitoring, and cell culture density measurement at OD600. The stability of the double beam system is critical for time-course studies where measurements must be reliable over extended periods.<\/span><\/p>\n<h3><b>Environmental Testing and Water Quality<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Environmental laboratories use the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> to detect and quantify nitrates, phosphates, heavy metals, organic pollutants, and dissolved substances in drinking water, groundwater, wastewater, and industrial effluents\u2014supporting compliance with BIS, EPA, WHO, and CPCB water quality standards.<\/span><\/p>\n<h3><b>Food and Beverage Quality Control<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Food testing laboratories rely on the <\/span>dual beam UV spectrophotometer<span style=\"font-weight: 400;\"> to measure vitamins, food colorants, preservatives, antioxidants, and contaminants in food and beverage products\u2014ensuring compliance with FSSAI and international food safety standards.<\/span><\/p>\n<h3><b>Chemical and Industrial Laboratories<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Chemical manufacturers use the <\/span><b>double beam UV-Vis spectrometer<\/b><span style=\"font-weight: 400;\"> to characterize dyes, pigments, reaction intermediates, and finished chemical products. The photometric stability of the double beam system ensures accuracy in long-duration reaction monitoring and complex multi-wavelength analyses.<\/span><\/p>\n<h3><b>Academic and Research Institutions<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Universities and research centers use the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> for teaching analytical chemistry, characterizing novel compounds, studying photochemical reactions, and conducting interdisciplinary research across chemistry, biology, materials science, and environmental science disciplines.<\/span><\/p>\n<h2><b>Lasany International: India&#8217;s Leading Double Beam UV Spectrophotometer Manufacturer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">When sourcing a high-performance <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> in India, <\/span><b>Lasany International<\/b><span style=\"font-weight: 400;\"> is the name laboratories trust. Established in 1998 and headquartered at SCF-132, Sector 17, Panchkula, Haryana, <\/span><b>Lasany International<\/b><span style=\"font-weight: 400;\"> is one of the original and largest manufacturers, importers, and exporters of spectrophotometers in India and global markets\u2014with an impressive track record of over 500,000 units sold across 97 countries worldwide.<\/span><\/p>\n<h3><b>Lasany International&#8217;s Double Beam UV Spectrophotometer Range<\/b><\/h3>\n<p><b>Lasany International<\/b><span style=\"font-weight: 400;\"> offers a comprehensive lineup of <\/span>Double Beam UV Spectrophotometers<span style=\"font-weight: 400;\"> engineered for laboratories of every scale and application profile:<\/span><\/p>\n<p><b>LI-2702<\/b><span style=\"font-weight: 400;\"> \u2014 Double Beam Microprocessor UV-VIS Spectrophotometer with a two-cell holder and Bluetooth-enabled Android software for wireless data transfer and remote operation.<\/span><\/p>\n<p><b>LI-2802 R<\/b><span style=\"font-weight: 400;\">\u2014Double Beam Microprocessor UV-VIS Spectrophotometer with Peltier temperature control system and automated sipper for temperature-sensitive kinetics studies and high-throughput sample analysis.<\/span><\/p>\n<p><b>LI-2900<\/b><span style=\"font-weight: 400;\"> \u2014 Double Beam Microprocessor UV-VIS Spectrophotometer with a large touchscreen interface, ARM chip control, and advanced analytical software supporting photometry, scanning, quantitative analysis, kinetics, and multi-wavelength measurement.<\/span><\/p>\n<p><b>LI-2904<\/b><span style=\"font-weight: 400;\"> \u2014 Double Beam UV-VIS Touch Screen Spectrophotometer with an 8-inch colour touchscreen, covering 190\u20131100 nm with \u00b10.3 nm wavelength accuracy and 1200 lines\/mm holographic grating.<\/span><\/p>\n<p><b>LI-3001<\/b><span style=\"font-weight: 400;\"> \u2014 Double Beam Xenon Flash Lamp Spectrophotometer offering superior stability, precision, and accuracy through continuous lamp drift correction\u2014the most advanced <\/span>double beam UV-Vis spectrometer<span style=\"font-weight: 400;\"> in the Lasany range.<\/span><\/p>\n<h3><b>Why Laboratories Around the World Choose Lasany International<\/b><\/h3>\n<p><b>Cutting-Edge Optical Technology<\/b><span style=\"font-weight: 400;\"> \u2014 Lasany International&#8217;s <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> use new-generation optical bench designs with ARM chip control, holographic diffraction gratings, and high-sensitivity silicon photodiode or PMT detectors\u2014delivering performance that rivals premium international brands.<\/span><\/p>\n<p><b>GLP and Regulatory Compliance<\/b><span style=\"font-weight: 400;\"> \u2014 Every <\/span><b>double beam UV-Vis spectrometer<\/b><span style=\"font-weight: 400;\"> from Lasany International includes built-in GLP compliance features\u2014audit trails, data logging, time\/date stamping, and user access management\u2014ready for NABL, ISO, GMP, and GLP accreditation audits.<\/span><\/p>\n<p><b>Global Export Confidence<\/b><span style=\"font-weight: 400;\"> \u2014 Lasany International exports its <\/span>Double Beam UV Spectrophotometers<span style=\"font-weight: 400;\"> to customers across Vietnam, Indonesia, Turkey, Brazil, Zimbabwe, Sri Lanka, Iran, Ghana, Colombia, the Philippines, Italy, Nigeria, Uganda, Israel, Kenya, and 97 countries in total\u2014proof that quality transcends borders.<\/span><\/p>\n<p><b>Exceptional After-Sales Support<\/b><span style=\"font-weight: 400;\"> \u2014 Every instrument is backed by <\/span><b>Lasany International&#8217;s<\/b><span style=\"font-weight: 400;\"> pan-India service network, including on-site installation, operator training, annual performance qualification, preventive maintenance, and rapid spare parts supply \u2014 ensuring maximum instrument uptime and analytical reliability.<\/span><\/p>\n<h2><b>Single Beam vs. Double Beam UV Spectrophotometer: Which Is Right for You?<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>Single Beam<\/b><\/td>\n<td><b>Double Beam UV Spectrophotometer<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Baseline Correction<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Manual, sequential<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Automatic, simultaneous<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Lamp Drift Compensation<\/span><\/td>\n<td><span style=\"font-weight: 400;\">None<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Continuous real-time<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Wavelength Scanning<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Limited<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Full-spectrum, high-speed<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Kinetic Studies<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Not suitable<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Excellent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Photometric Stability<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Moderate<\/span><\/td>\n<td><span style=\"font-weight: 400;\">High<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">GLP Compliance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Basic<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Full<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Best For<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Routine single-point QC<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Research, scanning, regulated labs<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">For any application involving wavelength scanning, time-based measurement, high-precision quantitative analysis, or regulatory compliance\u2014the <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> is unquestionably the superior investment.<\/span><\/p>\n<h2><b>Best Practices for Accurate Double Beam UV Spectrophotometer Results<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Getting the best analytical performance from your <\/span>UV-Vis dual beam spectrophotometer<span style=\"font-weight: 400;\"> requires disciplined laboratory practice:<\/span><\/p>\n<p><b>Warm-Up Time<\/b><span style=\"font-weight: 400;\"> \u2014 Allow 20\u201330 minutes of warm-up before measurements to ensure lamp and detector stability.<\/span><\/p>\n<p><b>Matched Cuvettes<\/b><span style=\"font-weight: 400;\"> \u2014 Always use optically matched cuvettes for sample and reference compartments to eliminate path-length discrepancy errors.<\/span><\/p>\n<p><b>Daily Baseline Correction<\/b><span style=\"font-weight: 400;\"> \u2014 Even with automatic correction built in, perform a fresh baseline scan with your blank before each analytical session.<\/span><\/p>\n<p><b>Wavelength Verification<\/b><span style=\"font-weight: 400;\"> \u2014 Periodically verify wavelength accuracy using holmium oxide glass or mercury emission lines per pharmacopoeial specifications.<\/span><\/p>\n<p><b>Cuvette Cleanliness<\/b><span style=\"font-weight: 400;\"> \u2014 Inspect cuvettes for scratches, fingerprints, and residue before every use. Even minor contamination significantly affects <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> readings.<\/span><\/p>\n<p><b>Stray Light Check<\/b><span style=\"font-weight: 400;\"> \u2014 Verify stray light performance using potassium chloride or potassium iodide solutions at specified wavelengths\u2014especially important for regulated laboratory environments.<\/span><\/p>\n<h2><b>Conclusion: Precision Starts with the Right Double Beam UV Spectrophotometer<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The <\/span><a href=\"https:\/\/lasany.org\/product\/double-beam-microprocessor-uv-vis-touch-screen-spectrophotometer-with-software\/\"><b>Double Beam UV Spectrophotometer<\/b><\/a><span style=\"font-weight: 400;\"> is far more than a light-measuring device\u2014it is a cornerstone of modern analytical science that enables discovery, ensures quality, protects public health, and drives compliance across dozens of industries worldwide. Its simultaneous dual-beam optical design, automatic baseline correction, and comprehensive multi-mode software make it the most reliable and versatile UV-Vis instrument available for any serious laboratory.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For laboratories and industries across India and globally seeking a high-performance <\/span>Double Beam UV Spectrophotometer<span style=\"font-weight: 400;\"> backed by over 25 years of manufacturing excellence, <\/span><a href=\"https:\/\/lasany.org\/\"><b>Lasany International<\/b><\/a><span style=\"font-weight: 400;\"> is the trusted partner that delivers world-class analytical capability at competitive pricing\u2014with the after-sales expertise to keep your instrument performing at its peak for years to come.<\/span><\/p>\n<h4><b>Get in Touch with Us: \u2013<\/b><\/h4>\n<p class=\"post__text\">Panchkula, Haryana<br \/>\n<strong>Website :-<\/strong>\u00a0<a href=\"https:\/\/lasany.org\/\">https:\/\/lasany.org\/<\/a><br \/>\n<strong>Address :-<\/strong>\u00a0SCF-132, Sector 17, Panchkula, Haryana 134109<br \/>\n<strong>Email :-<\/strong>\u00a0 lasanyinternationalindia@gmail.com<br \/>\n<strong>Online Support :- 9888911439 \/ 9803017479<\/strong><\/p>\n<p class=\"post__text\">If you are looking for Laboratory, Analytical, and Medical Products, then\u00a0<a href=\"https:\/\/lasany.org\/\"><strong>Lasany International<\/strong>\u00a0\u00a0<\/a>is the perfect choice for you.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In any analytical laboratory, the ability to measure how substances interact with light is fundamental to almost every scientific discipline. From testing the purity of a pharmaceutical compound to monitoring pollutants in water, quantifying protein concentrations in biological samples, or controlling the quality of industrial chemicals, light-based measurement is at the core of it all. &hellip; <\/p>\n<p class=\"more-link-wrap\"><a href=\"https:\/\/lasany.org\/vi\/double-beam-uv-spectrophotometer-complete-guide-to-precision-optical-analysis\/\" class=\"more-link\"><i class=\"opal-icon-plus\" aria-hidden=\"true\"><\/i><span>Read More<span class=\"screen-reader-text\"> &#8220;Double Beam UV Spectrophotometer : Complete Guide to Precision Optical Analysis&#8221;<\/span><\/span><\/a><\/p>\n","protected":false},"author":3,"featured_media":10897,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"pgc_meta":"","_eb_attr":"","inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[100],"tags":[359,356,121,357,358,307,137],"class_list":["post-10896","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-laboratory-equipment","tag-double-beam-spectrophotometer","tag-double-beam-uv-spectrophotometer","tag-double-beam-uv-vis-spectrophotometer","tag-double-beam-uv-visible-spectrophotometer","tag-touch-screeen-double-beam-uv-vis-spectrophotometer","tag-uv-vis-double-beam-spectrophotometer","tag-uv-visible-spectrophotometer"],"_links":{"self":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/posts\/10896","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/comments?post=10896"}],"version-history":[{"count":6,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/posts\/10896\/revisions"}],"predecessor-version":[{"id":10974,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/posts\/10896\/revisions\/10974"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media\/10897"}],"wp:attachment":[{"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/media?parent=10896"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/categories?post=10896"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lasany.org\/vi\/wp-json\/wp\/v2\/tags?post=10896"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}